Answer
$\dot{Q}_L=132\ kJ/min$
$COP=1.57$
Work Step by Step
$\dot{Q}_L=\dot{m}c_p(T_1-T_2)$
Given $\dot{m}=215\ kg/h,\ c_p=3.35\ kJ/kg.°C,\ T_1=24°C,\ T_2=13°C$:
$\dot{Q}_L=132\ kJ/min$
$COP_R=\dot{Q}_L/\dot{W}_i$
With $\dot{W}_i=1.4\ kW$