Chapter 11 - Refrigeration Cycles - Problems - Page 643: 11-49C

Answer

See explanation

Work Step by Step

The saturation pressure of refrigerant $-134a$ at $-32^{\circ}C$ is $77\text{ kPa}$, which is below the atmospheric pressure. In reality a pressure below this value should be used. Therefore, a cascade refrigeration system with a different refrigerant at the bottoming cycle is recommended in this case.